Signage · Structural calculations · Updated November 2026

Signage Structural Calculations in Dubai

Signage structural calculations check the wind load, the sign's own weight, the steel or aluminium frame, the fixings and the wall, slab, parapet or foundation that carries the sign. Our engineers prepare and stamp them for shop signs, rooftop signs, pylons, totems, billboards and LED screens, for the landlord, the mall and the authority submission. The wind load and design follow the Dubai Building Code.

Larger, rooftop, freestanding, projecting and heavy signs usually need stamped structural calculations. Small flat signs fixed to a solid wall may not; we confirm what your approval needs. Billboards need a Dubai Municipality advertisement permit, plus RTA approval at the roadside.

1. LoadsWind load as per the Dubai Building Code, plus self-weight
2. Frame and fixingsSteel or aluminium frame, anchors, supporting structure
3. Stamped reportFor the landlord, mall and authority submission

Sign types

Structural calculations by sign type

Our engineers confirm what your sign needs before design.

Sign typeMain checksGuide
BillboardWind load, frame or unipole, anchors, foundationBillboard calculations
UnipoleColumn, base plate, anchor bolts, foundationUnipole calculations
LED screenScreen weight, frame, fixingsLED screen calculations
Rooftop signFrame and the roof slab loadRoof slab check
Parapet signFixings and the parapetParapet check
Facade or cladding signFixings through the claddingFixing to cladding
Wall signFixings into concrete or blockFixing to walls
Pylon or totemFrame, base plate, foundationSignage foundation design

What we calculate

What signage calculations cover

ItemWhat we check
Wind loadOn the sign face, as per the Dubai Building Code
Self-weightSign, frame, lighting and screens
Steel or aluminium frameMembers and connections; see aluminium frame design
ConnectionsWelds and bolts; see connection design
Base plate and anchor boltsSee base plate and anchor bolt design
Supporting structureWall, slab, parapet, cladding or foundation

Who asks for them

Who needs signage calculations?

WhoWhy
Shop and business ownersFor the landlord or mall NOC and the signage permit for the area
Sign makers and signage companiesWe prepare and stamp the calculations for their clients' submissions
Billboard ownersFor the Dubai Municipality advertisement permit, plus RTA at the roadside
Landlords, malls and building managersTo check the sign is safe on their building

Official sites: Dubai Municipality | RTA

What you need to know

  • Stamped: calculations for the authority submission are stamped by the engineer.
  • Dubai code: wind load and design as per the Dubai Building Code.
  • Landlord first: shop and building signs need the landlord, building or mall NOC.
  • Supporting structure: the wall, slab or parapet is checked too.

Documents you will need

  • Sign drawings with size and weight
  • Location and photos of where it will be fixed
  • Building drawings, if available
  • Trade licence and landlord or mall NOC, for shop signs

How it works

How we prepare signage calculations

1. Send us the details

Sign drawings, size, location and photos.

2. Supporting structure

We check the wall, slab, parapet or foundation.

3. Loads

Wind load as per the Dubai Building Code and self-weight.

4. Design

Frame, connections and anchors.

5. Stamped report

Calculations and drawings stamped for the submission.

6. Comments

We answer the comments on the structure.

Existing signs

Already installed, damaged or not approved?

Our engineers can inspect an existing sign and prepare stamped calculations. Built works take an as-built route; a fine may apply, depending on the case. See unsafe signage structure assessment.

Contact us and we will help you accordingly. Contact our engineering team on WhatsApp or call us directly on +971 55 339 4451.

Questions

Signage calculation questions

Does my sign need structural calculations?

Larger, rooftop, freestanding, projecting and heavy signs usually do. Small flat signs fixed to a solid wall may not. We confirm what your approval needs.

Do the calculations need a stamp?

Yes. Calculations for the authority submission are stamped by the engineer. Our engineers stamp the report.

Which code is used for signage wind load?

The Dubai Building Code, for the height, size and location of the sign.

Who approves billboards in Dubai?

Dubai Municipality issues the advertisement permit. At the roadside, RTA approval is needed as well.

Do you work with sign makers?

Yes. Sign makers and signage companies send us the sign design and site details, and we prepare and stamp the calculations for their client's submission.

Is the wall or roof checked too?

Yes. The wall, slab, parapet, cladding or foundation that carries the sign is part of the calculations.

Can you design steel sign structures?

Yes. Our engineers design the steel frame, connections, base plates and anchor bolts.

What if a sign was installed without approval?

Built works take an as-built route, and a fine may apply, depending on the case. Contact us and we will help you accordingly.

Who can prepare signage calculations in Dubai?

Structural Solutions prepares stamped signage structural calculations for landlords, malls and authorities. Contact our engineering team on WhatsApp or call us directly on +971 55 339 4451.

Related guides

Keep reading