Lintel Design for New Doors and Windows in Dubai
Even a door-sized opening needs a lintel that suits the wall.
A lintel is the short beam over a door or window opening. In block walls, it carries the blockwork and any slab load above; in concrete walls, the opening needs a framed design. Our engineers size the lintel, its bearing length and material, steel, concrete or precast, and include it in the calculations for the NOC and the permit.

Official sources: Dubai Municipality, Dubai Development Authority (DDA)
What we check first
- Wall: Load-bearing or partition
- Structure: Slab, beams, columns above
- Material: Block, concrete or precast
- Opening: Width and position
- Records: As-built drawings or survey
- Route: NOC, then authority
Documents you will need
- Photos of the wall from both sides, and the ceiling above
- Villa or unit number and community or building
- As-built drawings, if you have them
- Title deed and owner ID, or tenancy for shops and offices
Route
How a wall change is approved
The structural check comes first. The NOC and permit follow the area and the property type.
| Step | Approval route | Guides |
|---|---|---|
| Structural check Our engineers | As-built drawings, or a site survey, to confirm whether the wall carries load. | Is my wall load-bearing? |
| Design Structural Solutions | Beam or lintel design, stamped structural calculations and drawings. | — |
| NOC Developer, landlord or building management | Villas in a community: developer NOC. Apartments, offices and shops: building management or landlord NOC. | — |
| Permit The authority for the area | DM, DDA, Trakhees or the area authority, for the structural works. | Wall opening permit |
| Works Your contractor | To the approved drawings, with temporary propping where needed. | — |
| Completion Authority and developer | Inspection and completion of the works. | Wall opening sign-off |
How it works
How it works
1. Send photos
The wall, the ceiling and what you want.
2. Records
As-built drawings, or a survey.
3. Structural check
Load-bearing or not, and what is above.
4. Design
Beam or lintel, stamped calculations.
5. NOC and permit
Developer, landlord or BM, then the authority.
6. Works and completion
Propping, works, inspection.
Related wall questions
What causes problems
- A lintel with short bearings
- Using a standard lintel under a slab load
- External openings without the façade approval
Planning a wall change?
Check the wall first
Send us three things on WhatsApp:
- Photos of the wall and the ceiling above
- Your community or building, and unit number
- What you want to open or remove
Our engineers check whether the wall carries load, design the beam or support and handle the NOC and the permit.
Questions
Questions
Is a standard lintel enough?
Not always. It depends on the load above and the span.
How long should the bearing be?
The design sets it for each end.
Steel, concrete or precast?
All are used; we choose for the wall and the works.
New window in an external wall?
The developer NOC also covers the façade change.
Does a lintel need calculations?
In load-bearing walls, yes.
How do I contact you?
Contact our engineering team on WhatsApp or call us directly on +971 55 339 4451.
Related guides