Column Restoration and Repair Approval (DDA)
Columns in car parks, basements and near the sea suffer from spalling, rusted steel bars and impact damage. Column repairs need propping and a repair design, and in DDA areas the repair goes to DDA with the specialist stamp.
Column damage usually starts at the base, where water and salts sit, or inside, where rusting bars split the cover. Columns carry the floors above, so the repair is propped and sequenced, and the repair design goes to DDA with the concrete restoration stamp.
Damage
Common column damage
Basement and car park columns, columns near the sea and columns hit by vehicles.
| Damage | Cause or sign |
|---|---|
| Spalling at the base | Water and salts at floor level |
| Rusted vertical bars | Section loss along the bars |
| Vehicle impact | Car parks and loading areas |
| Cracks along the bars | Corrosion starting inside |
Investigation
What we investigate
A testing laboratory carries out the tests; our engineers choose the tests and read the results.
| Check | How |
|---|---|
| Cover depth | Cover meter scan |
| Concrete strength | Cores, by a laboratory |
| Chlorides | Near the sea and in car parks |
| Load during repair | Propping design |
Repair
How a column repair is designed
The DDA route is on the concrete restoration stamp page.
| Part | Notes |
|---|---|
| Propping | Loads taken off the column before breaking out |
| Steel bar treatment or added bars | Where section is lost |
| Concrete repair | Repair mortar or concrete |
| Protection | Against water and impact |
Official sites: DDA | Dubai Building Code
What you need to know
- Cause first: water and salts at floor level.
- Restoration stamp on the repair design.
- Supervised repair works.
- Needs more strength? See column strengthening.
Documents you will need
- Photos of the column damage
- Building details
- Earlier reports, if any
How it works
Column repair, step by step
1. Survey
Cover depth.
2. Tests
Laboratory.
3. Design
Repair and method.
4. DDA
Stamp and approval.
5. Repair
Supervised.
Questions
Column restoration questions
Do I need DDA approval to repair a column?
Structural repairs do. We check your case and tell you if the repair is structural.
Does a damaged column need propping before repair?
Usually yes. We design the propping with the repair.
Is the restoration stamp different from the strengthening stamp?
It is the same strengthening specialist stamp. People call it the strengthening stamp, the concrete strengthening stamp, the concrete restoration stamp or the concrete repair stamp.