HVAC design for a retail fit-out in Dubai
HVAC design for a retail fit-out in Dubai covers the cooling load, the AC layout and the connection to the mall or building supply, stamped for approval.
Our HVAC design for shops, boutiques and showrooms starts with the cooling load calculation, from the floor area, lighting, people and display equipment. We then lay out the fan coil units or ducted AC, diffusers and fresh air, connected to the mall chilled water or the building AC system as the landlord guide requires, and coordinate it with the ceiling, sprinklers and lighting. The drawings are stamped for the mall and Civil Defence (DCD).

Official sources: Dubai Civil Defence · DEWA · Dubai Municipality
HVAC design for a retail fit-out: what you need to know
- Cooling load: Calculated from area, lighting, people and equipment.
- Layout: Units, ducts, diffusers and fresh air.
- Coordination: With ceiling, sprinklers and lighting.
- Tenant guide: Follows the mall or landlord requirements.
What to send us
- Interior design layout and ceiling plan
- Mall or landlord fit-out guide
- Lease or tenancy contract
- Trade licence
- Existing MEP drawings, if available
Who does what
From design to opening
We confirm the exact route for your mall or building.
| Step | Approval route | Guides |
|---|---|---|
| MEP design and calculations Structural Solutions | HVAC, lighting and power, fire alarm, sprinklers, plumbing, with calculations. | MEP package |
| Landlord or mall approval Consultant → mall or landlord | Stamped drawings reviewed by the mall or landlord fit-out team. | Consultant stamp |
| Authority permit, where needed Consultant → DM, DDA or Trakhees | Depending on the area and the mall or building. | Authority permit |
| Civil Defence (DCD) Structural Solutions → DCD | Fire and life safety approval, needed for every fit-out change. | DCD approval |
| Final inspection Mall, authority and DCD | DCD final inspection and completion before opening. | Sign-off |
How it works
How it works
1. Brief
Layout, ceiling plan and the landlord guide.
2. Design
MEP design and calculations.
3. Approvals
Mall or landlord, authority and DCD.
4. Handover
Final inspection and completion.
Questions
More questions about HVAC design for a retail fit-out
Do you size the AC units?
Yes, from the cooling load calculation.
Can I keep the existing AC?
We check whether it suits the new layout and load.
Does HVAC need DCD approval?
The fire and smoke side is part of the DCD review.
Do you prepare a BOQ?
No, we prepare the design and calculations.
Related guides